Why is the hydraulic pump flow fail to reach the rated value? How to solve it?

Reason 1: The speed does not reach the rated speed.
Troubleshooting: Select the generator speed specified in the manual.

Reason 2: There are leaks in the system.
Troubleshooting: Inspect the system and repair any leak points.

Reason 3: Prolonged operation of the oil pump causing vibration and loosening of the pump cover screws.
Troubleshooting: Tighten the screws appropriately.

Reason 4: Air leakage in the suction pipeline.
Troubleshooting: Check all connections, seal and secure them.

Reason 5: Insufficient oil suction due to low oil level in the tank.
Troubleshooting: Refill oil to above the minimum oil level mark.

Reason 6: Clogging of the inlet oil filter.
Troubleshooting: Clean the filter or use an oil filter with a flow rate of at least twice the pump flow rate.

Reason 7: Blockage or small diameter in the suction pipeline.
Troubleshooting: Clean the pipeline and use a suction pipe with a diameter not less than the pump inlet.

Reason 8: Oil viscosity too high or too low.
Troubleshooting: Use the recommended viscosity of working oil.

Reason 9: Improper flow adjustment of the variable pump.
Troubleshooting: Re-adjust to the required flow.